A significant change is due to be implemented in 2025 in the European electricity market: Prices will be set per...
Latest posts
-
Transition to 15-minute pricing in the European electricity marketRead more -
Assumed bug on Aidon meters with HAN-NVE interface13-Feb-2025Read moreWe assume this is a bug on Aidon smart meters with HAN-NVE interface (Norway, Sweden and possibly Finland).
-
Kamstrup Omnipower scale errors on some parameters (known to happen in Sweden and Denmark)17-Jun-2024Read moreSome grid companies have increased the number of decimals on some parameters, here is how to update your device.
-
Updating device over USB cable, simplified method16-Apr-2024Read moreSome users experience difficulties using one of the Over-the-air (OTA) methods for firmware upgrade. We propose a...
-
Kamstrup Omnipower HAN port not working29-Feb-2024Read moreHow to cure the Kamstrup Omnipower meter hick-up (meter stops pushing data)
-
Kamstrup Omnipower meters in Sweden: Which configuration should you choose?19-Jan-2024Read moreSwedish grid companies are moving from "HAN-NVE" configuration to "P1" configuration. Some grid companies allow their...
-
L2 current not available!?11-Jan-2024Read moreSome users have noticed that the device is no longer reporting current on phase L2.
-
Swedish customers and PostNord as "Tullombud"21-Sep-2023Read moreSwedish customers receiving our shipments via Postnord are mislead to think they have to pay customs fee and VAT....
-
One-click upgrade is not working05-Jul-2023Read moreOne-click firmware upgrade works just fine for most users - but what to do if it fails?
-
Blog categories
Search in blog
Kamstrup Omnipower HAN port not working
The Kamstrup Omnipower meter is a very popular smart meters, installed in millions of sites in a number of countries.
However, its HAN port seems to have a flaw that some of us have been unfortunate to experience: After having delivered data to the HAN port every 10 seconds for months or years, the port suddenly stops sending data. It continues delivering voltage and power to attached equipment, there is just no data.
If this happens to you and your installation has the main breaker on the "street side" of the Omnipower meter you can consider yourself lucky: Just cut power from the meter by opening the main breaker, wait a few seconds, then close the breaker again. Problem solved!
In some countries (for instance Denmark) the main breaker is typically situated on the other side of the meter, so there is no way to cut its power. This is a more tricky situation.
This is what we have found after having investigated the issue:
If you are in Denmark and Radius is your grid company (Copenhagen and surrounding region), it is relatively easy to fix this:
- Go to and fill out this web form: https://radiuselnet.dk/elnetkunder/krypteringsnoegle-til-elmaaler/bestil-de-to-noegler-til-dlms-cosem/
- In the comment field, indicate that you request a restart of the HAN port.
- You should receive an email from Radius requesting you to remove you reader from the meter and not re-insert it until you get a message confirming the port has been restarted
Note: There might be other grid companies that have outsourced the Omnipower meter management to Kamstrup. If you have this issue, contact your grid company and ask if they are able to request Kamstrup to do a remote restart of your meter.
So, what is the solution if the grid company says they cannot reset the HAN port?
In that case, we recommend you to insist that they find a solution. The grid company owns the power meter, it stopped working - and it is not your fault. The grid company should send you (with no cost for you) an electrician/technician that can either disconnect/reconnect your power meter - or reboot it via the optical port of the meter. If they claim that it is the connected equipment that caused the disruption, you can tell them that the HAN port is still delivering power (which is confirmed if your Pow-K is still working, just not receiving data), so it is not an overload shutdown.
Related posts
-
How do I fix a bricked device?
Posted in: FAQ28-May-2022If you by a mistake uploaded over Wifi a wrong firmware (intended for an other microprocessor), the device will not...Read more -
Home Assistant med Pow-K
28-May-2022The Danish YouTube-channel Kenneths Teknik made an instructive video that shows how to connect a Pow-K to Home...Read more -
Can Pow-U and Pow-K show energy produced from solar panels or wind turbines?
Posted in: FAQ28-May-2022Especially solar panel installations are starting to become common, so we want to monitor power and energy from them!Read more -
How can I read data from my Pow-K / Pow-U when I'm not at home?
Many of us do not like the idea of sending our power consumption data to some cloud service where we do not really...Read more -
Pow-U: Can the external power be connected while Pow-U is connected to the meter?
Posted in: FAQ29-May-2022In some use situations, the Pow-U will have difficulties maintaining its voltage level and will reset frequently (see...Read more
Cookie preferences
Leave a comment
Comments
buffer 512 or 256
By: Preben Madsen On 08-Apr-2026Hi mine failed after i was in and edited the MQTT settings, here it was req. to change the buffer from 512 to 256 since then it has not receiving anything. I have contacted my friend there bought one as well. and here it is running fine 512.
Replied by: Egil Opsahl On 09-Apr-2026
Issue remains after meter disconnect
By: Christian On 25-Mar-2026My issue remains after I today got my installation upgraded (same meter but everything else in the installation box replaced, so the meter was physically disconnected for an hour). Does it still make sense to contact Radius (DK) or should the physical disconnection have fixed it?
I get a valid HAN message once in a while (up o maybe 10 min apart), but most are unknown.
This might not be the best place for debugging it (where should I ask this?)
My debug output via telnet shows this kind of thing:
(W) Used 1198ms to read HAN port (true)
(E) Ended up in default case while unwrapping...(tag 96)
(W) Unknown data received
(W) Used 1054ms to read HAN port (true)
(W) No HAN data received last 30s, single blink
(I) (PriceService) Price point reset
(W) No HAN data received last 30s, single blink
(W) No HAN data received last 30s, single blink
(W) Boundary flag missing
(W) Used 1166ms to read HAN port (true)
(E) Ended up in default case while unwrapping...(tag 4A)
(W) Unknown data received
Replied by: Egil Opsahl On 30-Mar-2026
Got the problem in SE
By: Thomas F On 07-Jan-2026FYI I also had this issue. Suddenly the Kamstrup meter just stopped reporting data.
I tried by unplugging the board over the night, but nothing happened.
So I had to cut the power on the main switch and after that it worked again as expected.
Is there an event from the AMS Reader when the HAN-port is dead?
I didn't check daily so I didn't noticed this for a while, but I guess that I just could have an automation in Home Assistant that notifies me when data is not received any more, but an error event from the board (MQTT) indicating what kind of problem would be nice (e.g. "No HAN data received").
Thanks for a nice product!
Cheers,
Thomas
Alternative HAN reset for DK
By: Høgni Z On 24-Jul-2025I had the problem with AMS Reader not recieving data from Kamstrup HAN port.
Then there was a power outtage, and the entire area went dark.
When power came back the HAN port was reset... Problem solved.
Replied by: Egil Opsahl On 28-Jul-2025
No access in my LAN
By: Lars K On 21-Oct-2024I can do the initial setup just fine, and my device (K+) connects, gets an IP address. But then there is no response - it seems like its blocked somehow. It has been working flawlessly for a long time until now.
I have tried resetting and factory defaults. It boots up fine, but wont let me see http pages over my LAN. Any advice?
Replied by: Egil Opsahl On 24-Oct-2024
Omnipower HAN port not working
By: Erik On 15-Oct-2024Thanks Egil for this post. I did pull out my Pow-K+ of the meter, because it did lost its wifi connection. Afterwards I did have this han connection error (or maybe earlier). Did write to Radius (Denmark) for at meter reset. Nice customer support - did responds fast - Kamstrup did reset the meter the day after and all works fine now. Radius/Kamstrup did ask me to pull out the Pow-K+ before reset , not sure this it is necessary, but did it anyway. Thank! /Erik
Replied by: Egil Opsahl On 24-Oct-2024